Abstract
Unlike the conventional transient hot-wire method for measuring thermal conductivity, the transient short-hot-wire method uses only one short thermal-conductivity cell. Until now, this method has depended on numerical solutions of the two-dimensional unsteady heat conduction equation to account for end effects. In order to provide an alternative and to confirm the validity of the numerical solutions, a two-dimensional analytical solution for unsteady-state heat conduction is derived using Laplace and finite Fourier transforms. An isothermal boundary condition is assumed for the end of the cell, where the hot wire connects to the supporting leads. The radial temperature gradient in the wire is neglected. A high-resolution finite-volume numerical solution is found to be in excellent agreement with the present analytical solution.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.