Abstract

Oxygen diffusivity and consumption in the human cornea have not been directly measured yet; current models rely on properties measured in vitro in rabbit corneas. The aim of this study was to present a mathematical model of time-dependent oxygen diffusion that permits the estimation of corneal consumption and diffusivity. The current oxygen diffusion model was extended to include the temporal domain and was used to simulate in vivo noninvasive measurements of tear oxygen tension in human corneas. The new model reproduced experimental data successfully, provided values for corneal diffusivity and consumption, and described the relationship between oxygen consumption and oxygen tension in the cornea. Estimated values were three times higher than those reported previously in in vitro rabbit experiments. This model allowed for the further investigation of oxygen transport in the cornea, including a better mathematical description and a determination of the transport properties of the cornea and the specific oxygen uptake rate of the tissue. The combination of this model and tear oxygen tension measurements can be useful in determining the individual oxygen uptake rate and exploring the relationship between oxygen transport and corneal abnormalities.