Abstract

In photoacoustic and ultrasound imaging, optical transducers offer a unique potential to provide higher responsivity, wider bandwidths, and greatly reduced electrical and acoustic impedance mismatch when compared with piezoelectric transducers. In this paper, we propose a total-internal-reflection-based Fabry–Pérot resonator composed of a 12-nm-thick gold layer and a dielectric resonant cavity. The resonator uses the same Kretschmann configuration as surface plasmon resonators (SPR). The resonators were analyzed both theoretically and experimentally. The experimental results were compared with those for an SPR for benchmarking. The 1.9-μm-thick-PMMA- and 3.4-μm-thick-PDMS-based resonators demonstrated responsivities of 3.6- and 30-fold improvements compared with the SPR, respectively. The measured bandwidths for the PMMA, PDMS devices are 110 MHz and 75 MHz, respectively. Single-shot sensitivity of 160 Pa is obtained for the PDMS device. The results indicate that, with the proposed resonator in imaging applications, sensitivity and the signal-to-noise ratio can be improved significantly without compromising the bandwidth.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call