Abstract
A three-tiered approach was developed to determine the influence of a chemically-diverse group of compounds exhibiting estrogen mimicry using recombinant human estrogen receptor (rhER) activity to calibrate a receptor protein-based biosensor. In the initial tier, a ligand competition array was developed to evaluate compounds inhibiting [3H]estradiol-17beta binding to rhER. Each of six different concentrations of [3H]estradiol-17beta was mixed with increasing concentrations of an unlabeled putative mimic. Each of these mixtures was incubated with a constant amount of rhERalpha and then receptor-bound [[3H]estradiol-17beta was measured. This array protocol analyzes ligand binding affinities of hERalpha with a potential inhibitor over the entire range of receptor protein saturation. When either hERalpha or hERbeta binds to an estrogenic ligand, the receptor monomer forms both homo- and hetero-dimers. Then the ligand-receptor dimer complex activates transcription by associating with an estrogen response element (ERE), which is a specific DNA sequence located upstream of estrogen-responsive genes. The second tier for ligand evaluation utilized an electrophoretic mobility shift assay (EMSA), which was performed with an ERE sequence labeled with [alpha[32]P]dATP and incubated with rhER in the presence or absence of unlabeled ligand. ERE-hER complexes were separated by electrophoresis and analyzed using phosphor imaging technology. To assess biological effects of an estrogen mimic on expression of an ER-target gene, a yeast cell-based bioassay was constructed with recombinant DNA technology using Saccharomyces cerevisiae. Each of these engineered yeast cells contained a rhERalpha expression plasmid (YEpE12) and a separate reporter plasmid (YRG2) containing an ERE sequence upstream of a beta-galactosidase reporter gene. Incubation of these yeast cells with an estrogenic compound allows formation of ligand-hERalpha complexes, which recognize the ERE sequence regulating beta-galactosidase expression. Estrogenic compounds, which were evaluated as calibrators for ligand-based and ERE-based biosensors, elicit varying responses in each of the three tiers of the protocol.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.