This paper describes a full vector intensity probe which advances the field of sound intensity and sound source direction estimation using six matched rotating and variable directional microphones. The probe has three pairs of microphones at an equal spacing of 30 mm that are set up in each of the x, y, and z directions and share the same observation point. The calibration method using the rotating microphone system is effective to correct position errors in the y- and z-axes microphone pairs. Sound intensity measurements using the variable directional microphone method can locate with accuracy a sound source, i.e., the structure parts radiating most acoustic energy. The system can find the maximum sound intensity level and beamwidth of the major lobe, and the peak sound intensity levels of the minor lobes. Therefore, a procedure for sound power determination based on minimum measurement data is theoretically and experimentally discussed. Consequently, it is possible to reconstruct only parts of the system emitting the most noise and measure efficiently the sound power level.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.