Abstract

This paper presents a three-phase integrated PET topology with capability of DC fault clearance based on the investigation of power electronic transformer topology (PET). The proposed PET has three ports of high-voltage AC, high-voltage DC and low-voltage DC, which can achieve the flexible access of distributed energy resources. The power unit of the PET adopts a three-phase integrated topology, and the single-phase fluctuating power in the DC-link capacitor is reduced by a 4-port DC/DC converter, thereby reducing the capacitance of the DC-link capacitor; Meanwhile, the power unit uses the clamp double sub-module(CDSM) to allow the self-clearing of the short-circuit fault on the high-voltage DC side. Finally, the paper verifies the proposed PET through EMT simulation and experimental prototype.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.