Abstract

This paper proposes the use of a three-phase high-frequency semicontrolled rectifier for wind energy conversion systems based on permanent magnet generators. The main advantages of the topology are: simplicity, since all active switches are connected to a common point, robustness, as short-circuit through a leg is not possible, and high efficiency due to reduced number of elements. As a disadvantage, higher but acceptable total harmonic distortion of the generator currents results. The complete operation of the converter and theoretical analysis are presented. Additionally, a single-phase pulsewidth modulation inverter is also employed in the grid connection. Experimental results on 5-kW prototype are presented and discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.