Abstract

A quasisteady multimode heat-transfer model for boiler concentric-tube overfire air ports has been developed that predicts the effect of geometry, furnace heat source and heat sink temperatures, axial injector wall conduction, and coolant flow rate on the tube wall temperature distributions. The model imposes a radiation boundary condition at the outlet tip of the ports, which acts as a heat source. The model was validated using field data and showed that both the airflow distribution in the ports and tube diameter can be used to control the maximum tube wall temperature. This helps avoid tube overheating and thermal degradation. For nominal operating conditions, highly nonlinear axial temperature distributions were observed in both tubes near the hot outlet end of the port.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.