Abstract
This letter proposes a novel junction temperature estimation method for the IGBT module to adapt to various operating conditions and improve the computing efficiency. By using the superposition theorem and odd/even mode analysis, the input power loss is decomposed into the even and odd mode loss. Further, the thermal model considering the thermal coupling between the upper and lower arms is equivalently decomposed into the even and odd mode thermal model according to the structure symmetry. The odd mode power loss is the cause of the thermal coupling between the upper and lower arms, and the odd mode junction temperature variation is used as an indicator to measure the thermal coupling. Based on the frequency domain analysis, the dividing line for operating condition with weak thermal coupling and strong thermal coupling can be obtained. Finally, experimental results verify the validity of the theoretical analysis and the accuracy of the proposed thermal estimation method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.