Abstract

Various parameters for a nickel SPND viz. neutron and gamma sensitivity, their dependence on detector dimensions, effect of activity build up during irradiation in the reactor on neutron sensitivity and burn up have been calculated using an analytical model by Warren and Shah. The results show that the main component of neutron sensitivity is due to neutron-induced capture gamma rays (99.93%). Delayed β signal is negligible and signal due to external gamma rays constitute about 0.06%. Low gamma sensitivity to external gamma rays, negligible activity buildup and low burn up rate make it a very promising prompt SPND for power reactors.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.