Abstract

An apparatus and a methodology to evaluate the thermal performance of window glazing are presented. Single glazings commercially available in Mexico are currently tested. During the test sequence, the glass samples are mounted in a specially designed calorimeter apparatus. The test is conducted in controlled laboratory conditions at the National Centre for Research and Technology Development in Mexico using a solar simulator test lamp. The calorimeter apparatus and the solar simulator test lamp were characterised and the overall heat loss coefficient U c measured was of 1.7±0.1 W/m 2°C. Overall heat transfer and shading coefficients are derived from the experimental results. The test method described allows the testing of practically any kind of glazing array. Glasses under investigation were of the reflective, absorbing coloured and common ones. This test method can be adequate to evaluate film coating glazing or multiple solar control coating glazing. Also, it can be of assistance to researchers, glass manufacturers and building designers in the development of rating and comparing of glazing options.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.