Abstract

The concentration of the chlorine in phosphate ester fire-resistant oils needs to be controlled strictly, because it is crucially related to the corrosion of debug system and it is considered as an important indicator to find the hidden faults. It is confirmed that the chlorine content can be tested accurately and conveniently using energy dispersive X-ray fluorescence (EDXRF) spectrometry, due to many advantageous features of this method, namely, rapid response, high sensitivity and good measure precision. The preparation of standard samples and the optimization of analytical conditions are discussed in this paper; then a series of experiments is performed to verify the accuracy of this method. Test results of the samples with chlorine content more than 10mg•kg-1 show that the precision of the proposed measurement method is above 89%, and its repeatability is above 97%. This work not only can provide a feasible method for the rapid detection of chlorine content in phosphate ester fire-resistant oils, but also gives a promising application in power industry

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.