Abstract

Due to the temperature fluctuation, both the self-gravity disturbance level of the gravitational wave detection vehicle and the laser interference measurement system are affected, which brings great noise to the gravitational wave measurement, and the temperature field fluctuation has become one of the most important noise sources of the inertial sensor. In order to ensure the noise level of the inertial sensor to meet the needs of detection, this paper uses the AC bridge to reduce the self-noise of the temperature measurement system, improve the resolution of the temperature measurement system, and realize a high-resolution and low-noise temperature measurement system. The experimental results show that the effective value of self-noise of the temperature measurement system is about 3.65 × 10[Formula: see text], and the long-period noise is less than 1 × 10[Formula: see text]. It can be used in the space gravitational wave detection test and control system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.