Abstract
There is a growing need to evaluate the esthetics of implant-supported crowns and bridges. An important tool for such an evaluation is standardized assessment of the soft and hard peri-implant tissue levels. A simple acrylic device has been developed for reliable and reproducible assessment of soft and hard peri-implant tissues using standardized color slides and standardized dental x-rays. With this device, changes in both the soft and hard tissues around implant-supported crowns can be evaluated as a function of time. The reproducibility of the technique was tested on color slides as well as on dental x-rays in a series of implant-supported crowns and their neighboring teeth. The reproducibility of this technique was excellent. The measuring errors for repeated measurements of the soft and hard tissues were 0.14 +/- 0.02 mm and 0.13 +/- 0.01 mm, respectively. The device is a reliable tool to assess changes in both soft and hard tissues around crowns and implants over time. Likewise, it is suggested that this technique also can be used to objectively assess soft and hard tissue changes around natural teeth with or without prosthetic restorations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.