Abstract

Magnetic beads coated with an anionic polymer, poly(methyl vinyl ether-maleic anhydrate) [poly(MVE-MA)], were used in a method to capture human immunodeficiency virus type-1 (HIV-1). The beads were incubated with either HIV-1-infected cell culture medium or plasma from HIV-1 infected individuals and separated from the supernatant by applying a magnetic field. After thorough washing, adsorption of HIV-1 by the beads was confirmed by reverse transcription (RT)-polymerase chain reaction (PCR), real-time PCR, enzyme-linked immunosorbent assay and western blotting. The results confirmed the presence of envelope, polymerase, Nef and the viral genome of HIV-1. Furthermore, various subtypes and circulating recombinant forms (CRFs) of HIV-1 including subtype B, C and CRF01_AE and the immature form of subtype B HIV-1 could be captured. Preincubation with neutralizing antibody against HIV-1 envelope gp41 decreased the capture efficiently, suggesting that poly(MVE-MA) binds HIV-1 via gp41. We believe that this capture procedure will be a valuable tool for detecting various types of HIV-1 in both clinical and experimental samples.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.