Abstract

A one-step model calibration methodology of the activated sludge model no. 1 (ASM1) of a full-scale wastewater treatment plant (WWTP) is proposed. First, the key parameters among all parameters of the ASM1 model are selected by sensitivity analysis based on the effluent quality index. Second, multiple response surface methodology (MRSM) is conducted to find the optimal parameter values of the ASM1 model. Lastly, an MRSM analysis is conducted in order to determine the optimal parameter values. This study was conducted in order to develop a new systematic model calibration methodology that can greatly help the modeler to find the optimal solution by selecting the key parameters and optimizing the parameters. In two case studies of simple activated sludge process and a full-scale plant, the experimental results indicated that the calibrated models can improve the prediction quality of the ASM model and the efficiency of the modeling.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.