Abstract

This paper describes a practical approach using an LC diode-array detector (DAD) and MS for the quantitation of B-group vitamins (thiamine, riboflavin, nicotinamide, pantothenic acid, pyridoxine, biotin, folic acid, and cyanocobalamin) in multivitamin supplements. The purpose of this study was to optimize the extraction and chromatographic conditions without application of internal standards to determine B-group vitamins in multivitamins. Chromatographic separation on a C18 column was optimized on the basis of chromatographic behavior depending on pH variation of the mobile phase. The optimized methods showed good r values, with RSD values lower than 2.44 and 3.09% for most of the B-group vitamins (except cyanocobalamin) using LC-DAD and LC-MS, respectively. The methods were also proved to be reproducible, with RSD values of 0.96 and 2.48% being obtained with LC-DAD and LC-MS, respectively. In addition, the developed analytical methods for B-group vitamins were validated using certified reference materials and were applied to commercially available multivitamin tablets.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.