Abstract

A system is considered where an unloaded ac generator is triggered to pulse an inductive load in a decaying train of oscillations. This is suitable for pulsing AGS ring multipoles where the required magnetic energy is a few kilojoules. The decaying oscillations serve to demagnetize the load. Since the output impedance of the generator is low and the magnetic coupling coefficient between stator and rotor is close to unity the short circuit currents are high and a significant amount of reactive energy is available for the load magnet.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.