Abstract

Computer-aided surgical planning has been widely used to increase the safety and predictability of surgery. The validation of the target of surgical planning to surgical outcomes on a patient-specific model is an important issue. The aim of this research was to develop a robust superposition method to assess the deviation of planning and outcome by using the symmetrical characteristic of the affected target. The optimal symmetry plane (OSP) of an object is usually used to evaluate the degree of symmetry of an object. We proposed a refined OSP-based contouring method to transfer a complex three-dimensional superposition operation into two dimensions. We compared the typical iterative closest point (ICP) algorithm with the refined OSP-based contouring method and examined the differences between them. The results using the OSP-based method were much better than the traditional method. As for processing time, the OSP-based contouring method was 11 times faster than the ICP method overall. The proposed method was not affected by the metallic artifacts from medical imaging or geometric changes due to surgical intervention. This technique can be applied for post-operative assessment, such as quantifying the differences between surgical targets and outcomes as well as performing long-term medical follow-up.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call