Abstract

By using the numerical simulation for the temperature field in the metal organic vapor deposition (MOCVD) reactor by induction heating, it is found that the temperature distribution in the conventional cylinder-shaped susceptor is nonuniform due to the skin effect of the induced current, which makes the temperature distribution of the wafer nonuniform. Therefore, a novel susceptor with a ∧-shaped slot is proposed. This slot changes the mode and the rate of the heat transfer in the susceptor, which improves the uniformity of the temperature distribution in the wafer. By using the finite element method (FEM), the susceptor with this structure for heating a wafer of four inches in diameter is optimized. It is observed that the optimized susceptor with the ∧-shaped slot makes the uniformity of the temperature distribution in the wafer improve by more than 85%, and a good uniformity of temperature distributions is kept under different wafer temperatures, which may be beneficial to the film growth.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.