Abstract
AbstractA focused survey of glazing system behavior in multi‐story buildings in the direct aftermath of Hurricane Andrew was conducted. Seventeen buildings and four building complexes were examined between 26 August and 30 August, 1992. The buildings surveyed spanned a 32 km (19 mile) distance from Miami on the north to Cutler Ridge on the south. With few exceptions, glazing systems performed poorly and damage to building contents was extensive. The following specific observations were made: (1) impacts from windborne debris were a dominant cause of glass failure; (2) wall system anchorages sometimes failed; (3) prevention of ‘blow‐through’ after internal pressurization significantly mitigated storm damage to building interiors; and (4) outer‐lite‐only failures occurred on some insulating glass units. Results of the survey underscore the vital importance of maintaining the integrity of a building envelope during a severe windstorm. Windborne debris must be considered in the design of architectural glazing systems, as must proper anchorages of glazing systems to building framing members.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.