Abstract

In 1985, serum samples were distributed to 27 laboratories within the UK and Eire with the objective of determining the current state of anti-platelet antibody detection. The sera included five unknown samples for blind assessment and four well-characterized reference reagents. The laboratories involved used a wide range of different methods but the most commonly used techniques were the fluorescent antiglobulin test and the enzyme-linked immunosorbent assay. In the trial, all responding laboratories were able to detect potent anti-platelet alloantibodies but there was a 43% incidence of 'false positive' results with samples which had been designated as inert. There were no apparent differences in performance between assays using fluorescein- or enzyme-labelled antiglobulin reagents or between assays which utilized PFA-treated rather than untreated platelets.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.