Abstract
The Perceval S sutureless valve prosthesis has recently been introduced as a new biological aortic valve prosthesis, but a specific learning curve is required, as for every cardiac surgical centre dealing with a new technique. After the removal of the stenotic valve, the prosthetic valve is correctly positioned within the mildly decalcified aortic annulus. When a supra-annular malposition occurs, due to an excessively rapid release of the prosthesis in the aorta or incomplete annular visualization, the Perceval S valve can safely be removed even after balloon dilation. The procedure performed is a 'χ-movement' with the aid of anatomical forceps. If the prosthesis does not show any malformation after the procedure, it can be reimplanted in the correct intra-annular position.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.