This brief presents a first-order low-pass filter topology capable of providing cutoff frequencies down to 2 mHz with power consumption of 5 nW. The circuit is intended for signal conditioning applications, particularly for use with very low frequency physiological signals in low-power portable medical equipment. To achieve a low-frequency cutoff, the filter is based around the use of a clocked transconductor, which provides low transconductance while using a relatively high bias current level. The circuit is implemented in a 0.35-μm technology with a 1-V supply and has 32- μVRMS measured noise and a 64-dB dynamic range. In terms of power consumption and cutoff frequency the reported filter outperforms previous filters from the literature.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Circuits and Systems II: Express Briefs
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.