Abstract

This brief presents a first-order low-pass filter topology capable of providing cutoff frequencies down to 2 mHz with power consumption of 5 nW. The circuit is intended for signal conditioning applications, particularly for use with very low frequency physiological signals in low-power portable medical equipment. To achieve a low-frequency cutoff, the filter is based around the use of a clocked transconductor, which provides low transconductance while using a relatively high bias current level. The circuit is implemented in a 0.35-μm technology with a 1-V supply and has 32- μVRMS measured noise and a 64-dB dynamic range. In terms of power consumption and cutoff frequency the reported filter outperforms previous filters from the literature.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.