Abstract
A subcable test facility was prepared to study ac losses and stabiilty of subsize cables under the pulsing magnetic field of a 40-kJ split-pair coil. A G-10 cryostat fabricated for the system has an inner diameter of 31 cm and is 170 cm deep. An 80-kW power supply for the coil has a pulsing mode of triangular operation. Another 500-kW power supply, rated for dc operation at 400 V and 1250 A, can have pulsing modes of triangular, trapezoidal, or ( <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">B + \dot{B}</tex> ) superimposed. AC losses of a superconducting composite strand with CuNi outer sheath were measured. Coupling losses among the strands were not significant because of the outer sheath.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.