Abstract

The present study aimed to determine the optimum levels of experimental factors that affect electroplating performance, i.e., filling via holes without defects. To this end, the Taguchi experimental design method was employed. The uniformity of plated Cu thickness was selected as the characteristic, and experimental conditions were determined using an orthogonal matrix array with respect to the selected experimental factors. The results were analyzed based on the signal-to-noise ratios acquired from experimental measurements. When the aspect ratio was low, the concentration of a leveler was found to be the determining factor. As the aspect ratio increased, the effect of current density and pulse time became more significant.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.