Abstract

This paper reports a study on BSCCO and ReBCO HTS (high temperature superconducting) test coils, layer-wound and double-pancake, with and without turn-to-turn insulation. Over current tests were performed in a bath of liquid nitrogen to compare stabilities of the test coils at 77 K. Saturation of magnetic fields from the NI (no insulation) coils, both BSCCO and ReBCO, was observed owing to current bypassing through turn-to-turn contacts in local quenches at operating currents higher than their critical currents. In the NI ReBCO coils, global quenches occurred at operating currents higher than the coil critical currents and quench recoveries were observed during discharge of the coils. The experimental results, obtained to date, demonstrate that the NI winding method enables remarkable improvement of thermal stability of the HTS coils.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.