Abstract
Two primary coolant pipes were narrow-gap multipass circumferentially butt welded by shielded metal arc welding (SMAW) method and then subjected to micro-hardness tests to distinguish the base metal (BM), heat affected zones (HAZs), fusion zones (FZs) and weld metal (WM). Subsequently, uniaxial tensile tests were performed to investigate the tensile properties on each area in SMAW welded joints. The fracture toughness has been investigated at the above four different locations of the SMAW welded joints. Then the 0.2mm offset line method and the stretch zone width method have been both employed to determine the critical initial fracture toughness Ji. The results indicate that the fusion zones (FZs) have the worst fracture toughness compared with other locations over weld joints.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.