Abstract

Dissolved-ozone flotation (DOF) is a tertiary wastewater treatment process, which combines ozonation and flotation. In this paper, a pilot-scale DOF system fed by secondary effluent from a wastewater treatment plant (WWTP) in China was used to study the effect of ozone dosage on the DOF process performance. The results show that an ozone dosage could affect the DOF performance to a large extent in terms of color and organic matter removal as well as disinfection performance. The optimal color and organic matter removal was achieved at an ozone dosage of 0.8 mg/l. For disinfection, significant improvement in performance could be achieved only when the organic matter removal was optimal. The optimal ozone dosage of at least 1.6 mg/l was put forward, in this case, in order to achieve the optimal color, turbidity, organic matter and disinfection performance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.