This study was performed to analyze the carbonation of the tunnel linings concentrating on the 7 public service-in road tunnels in Korea and to commpare the trend of carbonation as to ventilation systems. The progress of carbonation in study was more conspicuous at the end of tunnels than the beginning of it. Likewise, it was remarkable in the tunnels of semi-transverse ventilation and transverse ventilation system rather than natural ventilation system, because traffic and other contaminants are more in such ventilation systems. (A) This paper was presented at Safety in the underground space - Proceedings of the ITA-AITES 2006 World Tunnel Congress and the 32nd ITA General Assembly, Seoul, Korea, 22-27 April 2006. For the covering abstract see ITRD E129148. Reprinted with permission from Elsevier.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.