Abstract
Solder joints which had fell from the electroless nickel/immersion gold (ENIG) pads during the assembly process after reflow were studied in this paper. In order to probe the root cause of the failure in solder joints, cross section and Scanning Electron Microscopy/Energy Dispersive X-ray (SEM&EDS) techniques were applied. In addition, solderability test was also put forward to verify the failure phenomenon. Results showed that, because of the serious corrosion of Ni layer on pad, the interface intermetallic compound (IMC) layer of test samples formed badly, which resulted in the insufficient mechanical strength of solder joints and caused crack or fell off. The Ni-corrosion resulted from poor ENIG process.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.