Abstract

The effects of the shape of the blade, the tip clearance and the sectional profile of the tip blade on fan noise were investigated experimentally. Analyzing the boundary layer for the suction side of blade, the effects of the seperation point on sound pressure level were clarified. It was found that the most suitable construction for the fan noise reduction was the blade inclined toward the rotative direction, the small tip clearance and the cut-off blade of the tip section in the pressure side.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.