Abstract

ABSTRACTA lab-scale electrodialysis (ED) which consisted of 11 pieces of cation-exchange membranes and 10 pieces of anion-exchange membranes was used to treat concentrated brine of Reverse osmosis (RO) membrane. The effect of operating parameters such as applied voltage, flowrate, and operating mode was investigated to measure the performance of a lab-scale ED. Three different voltages (5, 10, and 15 V) and flowrates (20, 30, and 40 L/h) were applied in order to optimize the operating conditions of the ED system. The maximum TDS removal efficiencies were 85%, 97%, and 98% for 5, 10, and 15 V, respectively. It was concluded that the desalination efficiencies were almost the same at flowrates values of 20, 30 and 40 L/h. The TDS concentration of the treated brine in the concentrate compartment rises to the highest value of 25,400 mg/L with desalination rate of 92.5% after five cycle operation. Moreover, the desalinated brine can be used as fresh water.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.