Abstract

Although not fully understood, it is well recognized that optimal working of glass fibre sizings is necessary to maximize the performance of glass fibre reinforced polymer composites. It is important that the organic components in such sizings continue to function after exposure to the high temperatures often experienced during composite processing. This study presents the results on the thermal stability of polypropylene and epoxy compatible glass fibre sizings obtained using TGA, microbond adhesion measurement and composite mechanical testing. Test results indicate that the performance of commercial polypropylene compatible glass fibre sizings can be significantly compromised by thermo-oxidative degradation at normal composite processing temperatures. A significant reduction in composite performance is directly related to a loss of fibre-matrix adhesion caused by thermal degradation of some of the principal sizing components.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.