Abstract

Abstract This is a study of the suitability of preheat flame electrical resistance as a potential method for measuring the standoff distance an oxyfuel cutting torch and a work piece. Careful scrutiny of forty-seven individual experiments demonstrate that when cut quality is good, there is a linear repeatable relationship between the two with uncertainty about ±0.3 mm (0.015 in.). As the cut quality degrades, the formation of top-edge dross reduces the electrical path length in the flame, and momentary reduction in the reaction rate in the kerf reduces the free electrons in the flame, causing increases in flame resistance. In these conditions, measurement uncertainty reduces to ±1 mm (0.040 in.) or worse.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.