Abstract
To better understand how the electric power generated from PZT piezoelectric ceramics is affected by mechanical loading conditions the power generation was examined during cyclic loading under various loading conditions. The electric power generation was continuously examined using a monitoring system that we have recently developed. This system revealed that the electric power increased with increase of the applied load but then decreased when the applied load exceeded a certain level. In addition, greater electric power was generated with a simple beam configuration compared with a cantilevered beam. The change of electric power generation was directly related to the stress direction; high stress in the tetragonal structure parallel to the c-axis gave rise to high electric power generation. On the other hand, material failure, including domain switching and crack generation, caused a reduction of the electric power generated. Based upon our experimental data, suitable loading conditions to give high piezoelectric energy generation have been clarified.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.