Abstract
The effect of a geometric nonlinearity on the Ibrahim Time Domain (ITD) modal data analysis technique has been studied using two analytically derived models and one laboratory model. Response data for the three models were analyzed by the ITD method. Indicators of nonlinear response were found which include harmonically related frequencies with repetitive mode shapes, clusters of frequencies in a narrow band around each harmonic, and variations in frequency with amplitude of oscillation. Also,for the cases studied, the presence of a nonlinearity has no detrimental effect on identifying linear responses. A potential for applying the algorithm to the identification of a certain class of nonlinear system was indicated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have