Abstract
The mass flow rate measurement using a critical nozzle shows the validity of the inviscid theory, indicating that the discharge coefficient increases and approaches unity as the Reynolds number increases under the ideal gas law. However, when the critical nozzle measures the mass flow rate of a real gas such as hydrogen at a pressure of hundreds bar, the discharge coefficient exceeds unity, and the real gas effects should be taken into account. The present study aims at investigating the flow features of the critical nozzle using high-pressured hydrogen gas. The axisymmetric, compressible Navier-Stokes computation is employed to simulate the critical nozzle flow, and a fully implicit finite volume method is used to discretize the governing equation system. The real gas effects are simulated to consider the intermolecular forces, which account for the possibility of liquefying hydrogen gas. The computational results are compared with past experimental data. It has been found that the coefficient of discharge for real gas can be corrected properly below unity adopting the real gas assumption.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.