Abstract

Abstract At present, there is no appropriate measurement techniques for space charge. In this paper, a U-shaped cavity device is developed as the space charge measurement device, which can be applied to transmission lines. Its design principle and calculation techniques of design parameter are also introduced. To test the space charge measurement accuracy of the U-shaped cavity device, a space charge generator is developed specifically for this experiment. The test results are excellent and show that the U-shaped cavity device can meet the design requirements. This technique is suitable for space charge measurement under transmission line normally charged work condition.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.