Abstract

A novel 9 GHz measurement system with thermal noise limited sensitivity has been developed for studying the fluctuations in passive microwave components. The noise floor of the measurement system is flat at offset frequencies above 1 kHz and equal to -193 dBc/Hz. The developed system is capable of measuring the noise in the quietest microwave components in real time. We discuss the results of phase and amplitude noise measurements in precision voltage controlled phase shifters and attenuators. The first reliable experimental evidences regarding the intrinsic flicker phase noise in microwave isolators are also presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.