Abstract
A CeF3 crystal produced during early R&D studies for calorimetry at the CERN Large Hadron Collider was exposed to a 24GeV/c proton fluence Φp=(2.78±0.20)×1013cm−2 and, after one year of measurements tracking its recovery, to a fluence Φp=(2.12±0.15)×1014cm−2. Results on proton-induced damage in the crystal and its spontaneous recovery after both irradiations are presented here, along with some new, complementary data on proton-damage in lead tungstate. A comparison with FLUKA Monte Carlo simulation results is performed and a qualitative understanding of high-energy damage mechanism is attempted.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.