Abstract

The flow field in a steam control valve is investigated by using the 2-D experiment and CFD to clarify the causes of serious pressure fluctuations. The experiments are carried out by changing the pressure ratio and valve opening ratio. Five types of flow patterns are observed in the experiment. Two types of them are stable and one of them is asymmetric attached flow and other is symmetric free jet flow. Three types are unsteady with symmetric, asymmetric oscillations and their mixture. These types of flows could be simulated by a 2-CFD fairly well. From these results, the characteristics of each flow fields are clarified.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.