Abstract

A CO 2 concentration of more than 1000 ppm has been monitored in Taiwanese bedrooms during sleeping hours in the wintertime. The high indoor CO 2 levels were caused by poor ventilation due to insufficient ventilation rates. This study sought to reduce the wintertime CO 2 concentration level in a typical Taiwanese bedroom with less outdoor air to maintain thermal comfort. CO 2 was used as an indicator to assess whether an adequate ventilation rate has been obtained to dilute or remove harmful pollutants. With the help of the thermal buoyancy effect, the CO 2 generated in the bedroom was effectively removed by means of less outdoor air. Through computational fluid dynamics simulations, the appropriate window and transom locations with the corresponding outdoor air supply volume, as well as the lowest possible outdoor air temperature were identified.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.