Abstract
DC reversal is a widely used technique for precise voltage measurement to remove DC offsets from the measurement signals. Herein, we propose a straightforward method using a DC reversal for the thermoelectric Thomson effect measurements. The proposed method allows the determination of Thomson coefficient from readily measurable quantities, that is, DC resistance, current, and the temperature changes caused by the Joule and Thomson effects, thereby removing the requirement of information on thermal conductivity and geometric values, which are required in a traditional DC-reversal method. Furthermore, this DC-based approach avoids typical complications experienced in recently developed AC-based methods, such as the absence of an AC current source or lock-in amplifier. The experimental results show that the Thomson coefficient of a fine Pt wire measured using the proposed method agrees well with a previously reported reference measurement with the expanded relative uncertainty of 6 %.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.