Abstract

Stator insulation quality assessment is an important issue for PWM inverter-fed machines, since the stator insulation is exposed to increased thermal/electrical stresses. In this paper, a new approach for monitoring the condition of the stator insulation for inverter-fed machines is proposed. The main concept of the proposed approach is to apply various types of test voltages to the motor stator insulation using the inverter, to perform standard off-line insulation tests whenever the motor is not operating. Two methods for testing the insulation with modifications to the inverter circuit are proposed and verified experimentally. The results show that the proposed technique provides a simple low cost solution for detecting stator insulation degradation at an early stage for reliable operation of inverter-fed machine systems, since the insulation condition can be monitored frequently. This not only helps prevent forced outages and safety risks due to insulation breakdown, but also helps perform maintenance in an efficient manner since individual motor maintenance can be prioritized and scheduled based on its present condition.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.