Abstract

Abstract Propulsion shaft torque measurement is essential in ship energy efficiency evaluation and emission control. Its accuracy and uncertainty influence decision making in terms of voyage optimisation and fuel consumption. For best results, the measuring device should be adjusted and calibrated adequately. This paper analyses the problem of ship propulsion shaft torque meter zero adjustment. Presented results of initial investigation suggest significant unrepeatability of the torque observed when the propulsion unit is at a standstill. Using a recently designed telemetry torque meter and an older analogue device a series of experimental research was conducted on board of a ship and on marine propulsion units installed in a laboratory. A new statistical method for zero adjustment is proposed and evaluated against methods commonly used on ships. The survey results suggest that the new method is burdened with a lower random error compared to presently used methods and uniquely allows for uncertainty evaluation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.