This paper presents a new calibration method of line scan camera model based on cross-ratio invariance using a calibration pattern on the top of the gauge block. Instead of using the 3D pattern, planner pattern with precise motion platform, or pre-calibrated matrix camera, only a planner pattern with gauge blocks is used in this new method. A group of data on the line scan camera projection plane is obtained by placing the planner pattern at a different height. Line scan camera parameters were calibrated through a derived mathematical model. This method is simple, inexpensive and easy to use. The experimental results demonstrated that the average reprojection error of this method is 0.0431, which is 62.2% lower than the traditional method, which proves the feasibility and effectiveness of this method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.