Abstract

A novel stability-indicating high-performance liquid chromatographic assay method was developed and validated for docetaxel in the presence of degradation products generated from forced decomposition studies. A gradient HPLC method was developed to separate the drug from the degradation products, using a Hichrom RPB HPLC column. Mixture of water and acetonitrile was used as mobile phase. The flow rate was 1.0 ml/min and the detection was done at 230 nm. Using the above method one can carry out the quantitative estimation of impurity namely DCT-1 and docetaxel. The developed gradient LC method was subsequently validated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.