Abstract

A simple, accurate, precise method was developed for the simultaneous estimation of the Segesterone acetate and Ethinyl estradiol in a tablet dosage form. The chromatogram was run through Discovery C18 150 x 4.6mm, 5mm column and mobile phase containing buffer 0.01N KH2PO4: Acetonitrile taken in the ratio 50:50 was pumped through the column at a flow rate of 1 ml/min. The temperature was maintained at 30°C. The optimized wavelength selected was 240.0 nm. Ethinyl estradiol and Segesterone acetate were eluted at 2.348 min and 3.855 min respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.