Abstract

A stability-indicating HPLC method for the quantitative determination of Bicalutamide is described. Bicalutamide is a nonsteroidal antiandrogen and is an oral medication that is used for treating prostate cancer. Separation was achieved on a Waters Symmetry shield RP18 HPLC column using a mobile phase consists of a mixture of phosphate buffer (Solvent A) and organic modifier acetonitrile (Solvent B). Degradation studies were performed on bulk samples of bicalutamide using acid (0.5 N methanolic hydrochloric acid), base (0.5 N methanolic sodium hydroxide), oxidation (10% v/v methanolic hydrogen peroxide), heat (60 °C) and UV light (254 nm). Degradation was observed under base hydrolysis to give the starting material used during the synthesis of bicalutamide. The degraded samples were assayed and gave a mass balance greater than 99.5%, thus proving the stability-indicating power of the developed method. The method was validated with respect to linearity, accuracy, precision and robustness.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.